SDS Volume (352)

Volume 37. Hydrocarbons in Water and Seawater, Part I, p 271

Original Measurements

Backx, P.; Goldman, S.; J. Phys. Chem. 1981, 85, 2975-9.

Variables:

Room Temp: 283 - 313 $\pu{K}$

Prepared by:

A. Maczynski

Method/Apparatus/Procedure:

In a 175-mL milk-dilution bottle fitted with a Bakelite screw cap and a Teflon insert and rotated end-over-end, (1) was equilibrated with an excess of (2), sampled with Hamilton syringes and titrated in an Aquatest II automatic Karl Fischer Titrator.

Source and Purity of Materials:
  1. Certified grade; washed with water, dried with silica gel, and distilled; $d^{25}$ = 0.77390.
  2. Obtained from the manufacturer; minimum isotopic purity of 99.7 atom% D.
  3. obtained from the manufacturer; minimum isotopic purity of 99.7 atom% D.
Estimated Errors:

Ambient temperature: ±0.01 K
Std. dev. of soly calcd from 18-32 determinations reported above.

Components:
  1. Cyclohexane, $\ce{ C6H12 }$; [110-82-7] NIST WebBook
  2. Water-d2, $\ce{ D2O }$; [7789-20-0] NIST WebBook
Experimental Data
Solubility of deuterium oxide in cyclohexane
$T$ ($\pu{K}$) $x_{2}$ MR2 (g2/100 g sln)
283 1.57 x 10-4 3.74 x 10-5
288 1.81 x 10-4 4.31 x 10-5
293 2.42 x 10-4 5.76 x 10-5
298 2.80 x 10-4 6.66 x 10-5
303 3.61 x 10-4 8.59 x 10-5
308 4.64 x 10-4 1.104 x 10-4
313 5.35 x 10-4 1.274 x 10-4

(a) Error, std. dev.

Download Data   link to XML output link to JSON output link to JSON-LD output