SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Swain, C. G.; Thornton, E. R.; J. Am. Chem. Soc. 1962, 84, 822-6.

Conditions:

Room Temp: 303 - 313 $\pu{K}$
Pressure: Pressure

Compiler:

A.L. Horvath

Methodology:

The measuring apparatus was described by Brown, et al. [1]. Iodomethane gas was admitted to the measurement apparatus from a storage bulb by distillation. The gas volume absorbed by water was determined using a gas buret. The temperature was controlled by a water bath and the equilibrium was aided by a magnetic stirrer in the equilibration bulb. The concentration in the solution was calculated from the pressure and volume measured.

Sample Information:
  1. Eastman Kodak Co., redistilled before use.
  2. Double distilled.
Measurement Errors:

Ambient temperature: ±0.01 K.
Mass concentration (m/v) (1): ±3%.
Pressure: ±0.05 mmHg.

Methodology Citation

1 Brown, H. C.; Taylor, M. D.; Gerstein, M. J.; Am. Chem. Soc. 1944, 66, 431.

System Components:
  1. Iodomethane, $\ce{ CH3I }$; [74-88-4] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) P/c (mmHg dm^3 mol^-1) 100w1 a $x_{1}$ $k_{\rm{H}}$ (m3 atm mol-1)
29.44 4.88 x 103 1.3971.793 x 10-36.421 x 10-3
29.45 4.9 x 103 1.3921.788 x 10-36.447 x 10-3
40.34 6.85 x 103 1.4781.900 x 10-39.013 x 10-3
40.35 6.92 x 103 1.4631.881 x 10-39.105 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output