SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Miller, M. M.; Wasik, S. P.; Huang, G. L.; Shiu, W. Y.; Mackay, D.; Environ. Sci. Technol. 1985, 19, 522-529.

Conditions:

Room Temp: 298 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

A saturated aqueous solution was prepared by passing water through a column which was packed with glass beads coated with bromochloromethane. The saturated solution was then pumped through an extractor column and bromochloromethane was extracted into an analytical column. The samples were analyzed with a liquid chromatograph equipped with both an UV absorbance and a fluorescent detector with excitation filters. The peak area was established using a Hewlett-Packard integrator.

Sample Information:
  1. Eastman Kodak Co., commercial quality, used as received.
  2. Double distilled.
Measurement Errors:

Ambient temperature: ±1 K (compiler).
Mass concentration (m/v) (1): Not specified.

System Components:
  1. Bromochloromethane, $\ce{ CH2BrCl }$; [74-97-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $C_{1}$ (mol/m3) 100w1 a $x_{1}$
25 129.0 1.6462.325 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output