SDS Volume (2382)

Volume 60. Halogenated Methanes with Water, p None

Original Measurements

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Variables:

Room Temp: 275 - 298 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 5 µL trichloromethane sample was injected into a 2.3 L equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The trichloromethane content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±10.0%.

Components:
  1. Trichloromethane, $\ce{ CHCl3 }$; [67-66-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
1.9 0.82511.254 x 10-368.9
13.5 0.78461.192 x 10-3128.7
15.7 0.75651.149 x 10-3146.7
17.1 0.76761.166 x 10-3155.0
22.0 0.76691.165 x 10-3194.5
24.9 0.82971.261 x 10-3204.8

(1) Gas-liquid system analysis parameter, from calibration measurements.

Download Data   link to XML output link to JSON output link to JSON-LD output