SDS Volume (2365)
Volume 60. Halogenated Methanes with Water, p None
Original Measurements
Karger, B. L.; Chatterjee, A. K.; King, J. W.; Tech. Rept. No. 3, Dept. of Chemistry, Northeastern Univ.; Boston, Mass.; May 10, 1971.
Variables:
Room Temp: 286 $\pu{K}$
Prepared by:
Method/Apparatus/Procedure:
Gas-liquid chromatography was used for the determination of the partition of trichloromethane with thin layers of water coated on Porasil D. Helium carrier gas was pre-saturated with water at the column temperature. The eluents were detected with an F. & M. flame ionization detector. The partition coefficient ($K_{\rm{L}}$) was calculated from the slope of the straight line plot of $V_{\rm{N}}/A_{\rm{L}}$ versus $V_{\rm{L}}/A_{\rm{L}}$.
Source and Purity of Materials:
- J. T. Baker Chemical Co., reagent grade.
- Distilled (compiler).
Estimated Errors:
Ambient temperature: ±0.05 K (compiler).
Mass concentration (m/v) (1): Not specified.
Components:
- Trichloromethane, $\ce{ CHCl3 }$; [67-66-3] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | 100w1 | $x_{1}$ | DL |
|---|---|---|---|
| 12.5 | 1.02 | 1.55 x 10-3 | 13.8 |
(1) Gas-liquid chromatographic parameter, from instrument calibration.