SDS Volume (2365)

Volume 60. Halogenated Methanes with Water, p None

Original Measurements

Karger, B. L.; Chatterjee, A. K.; King, J. W.; Tech. Rept. No. 3, Dept. of Chemistry, Northeastern Univ.; Boston, Mass.; May 10, 1971.

Variables:

Room Temp: 286 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

Gas-liquid chromatography was used for the determination of the partition of trichloromethane with thin layers of water coated on Porasil D. Helium carrier gas was pre-saturated with water at the column temperature. The eluents were detected with an F. & M. flame ionization detector. The partition coefficient ($K_{\rm{L}}$) was calculated from the slope of the straight line plot of $V_{\rm{N}}/A_{\rm{L}}$ versus $V_{\rm{L}}/A_{\rm{L}}$.

Source and Purity of Materials:
  1. J. T. Baker Chemical Co., reagent grade.
  2. Distilled (compiler).
Estimated Errors:

Ambient temperature: ±0.05 K (compiler).
Mass concentration (m/v) (1): Not specified.

Components:
  1. Trichloromethane, $\ce{ CHCl3 }$; [67-66-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
12.5 1.021.55 x 10-313.8

(1) Gas-liquid chromatographic parameter, from instrument calibration.

Download Data   link to XML output link to JSON output link to JSON-LD output