SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Glasoe, P. K.; Schultz, S. D.; J. Chem. Eng. Data 1972, 17, 66-8.

Conditions:

Room Temp: 288 - 308 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

The saturation of heavy water with tetrachloromethane was done in a closed system, protected from atmospheric moisture, and placed in a constant temperature water bath. The solubility of heavy water in tetrachloromethane was measured using the Karl Fischer titration method with a 'dead stop' end-point determination [1]. 15 Trials were done at each temperature.

Sample Information:
  1. Source not given, 99.8% pure, used as received.
  2. Source not given. Reagent grade, purified by distillation before use.
Measurement Errors:

Ambient temperature: ±0.1 K (compiler).
Mass concentration (m/v) (1): See above.

Methodology Citation

1 Wernimont, G.; Hopkinson, F. J. Ind. Eng. Chem., Anal. Ed. 1943, 272.

System Components:
  1. Water-d2, $\ce{ D2O }$; [7789-20-0] NIST WebBook
  2. Tetrachloromethane, $\ce{ CCl4 }$; [56-23-5] NIST WebBook
Experimental Data
$T$ (°C) $C_{1}$ (mol/m3) 100w1 a $x_{1}$ a
15 5.7 7.13 x 10-35.47 x 10-4
25 7.5 9.49 x 10-37.28 x 10-4
30 8.4 0.01078.21 x 10-4
35 10.3 0.01321.013 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output