SDS Volume

Volume 38. Hydrocarbons in Water and Seawater, Part II, p None

Source Publication

May, W. E.; Wasik, S. P.; Freeman, D. H.; Anal. Chem. 1978, 50, 997-1000

Conditions:

Room Temp: 6.6 - 29.9 °C

Compiler:

A. Maczynski

Methodology:

The dynamic coupled column liquid chromatography (DCCLC) method was based on generating saturated solutions by pumping water through a column packed with glass beads that have been coated with the component [1] (generator column). The concentration of [1] in the effluent of the generator column was measured by a modification of the coupled column liquid chromatographic process that has been described in [1].

Sample Information:
  1. Commercial product; less than 3% impurities.
  2. Distilled over $\ce{KMnO4}$ and $\ce{NaOH}$ and passed through a column packed with XAD-2 (Rohm and Hass, Philadelphia, Pa.)
Measurement Errors:

Ambient temperature: ±0.05°C
Mass concentration (m/v) (1): stand. dev. See above.

Methodology Citation

1 May, W.; Chesler, S.; Cram, S.; Gump, B.; Hertz, H.; Enagonio, D.; Dyszel, S.; J. Chromatogr. Sci. 1975, 13, 535.

System Components:
  1. 1-Methylphenanthrene, $\ce{ C15H12 }$; [832-69-9] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data

μg(1)/kg(2) = 55.42 + 6.8016 t + 0.1301 t2 + 0.0080 t3

$T$ (°C) $x_{1}$ MR1 (g1/100 g sln)
6.6 8.92 x 10-99.52 x 10-6
8.9 1.07 x 10-81.14 x 10-5
14.0 1.38 x 10-81.47 x 10-5
19.2 1.81 x 10-81.93 x 10-5
24.1 2.39 x 10-82.55 x 10-5
25.0 2.69 x 10-82.69 x 10-5
26.9 2.85 x 10-83.04 x 10-5
29.9 3.32 x 10-83.55 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output