SDS Volume
Volume 38. Hydrocarbons in Water and Seawater, Part II, p None
Source Publication
May, W. E.; Wasik, S. P.; Freeman, D. H.; Anal. Chem. 1978, 50, 997-1000
Conditions:
Room Temp: 6.3 - 31.1 °C
Compiler:
Methodology:
The dynamic coupled column liquid chromatography (DCCLC) method was based on generating saturated solutions by pumping water through a column packed with glass beads that have been coated with the component [1] (generator column). The concentration of [1] in the effluent of the generator column was measured by a modification of the coupled column liquid chromatographic process that has been described in [1].
Sample Information:
- Commercial product; less than 3% impurities.
- Distilled over $\ce{KMnO4}$ and $\ce{NaOH}$ and passed through a column packed with XAD-2 (Rohm and Hass, Philadelphia, Pa).
Measurement Errors:
Ambient temperature: ±0.05°C
Mass concentration (m/v) (1): Stand. dev. See above.
Methodology Citation
System Components:
- 2-Methylanthracene, $\ce{ C15H12 }$; [613-12-7] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
μg(1)/kg(2) = 2.78 + 0.8180 t + 0.0306 t2 + 0.0011 t3
| $T$ (°C) | $x_{1}$ | MR1 (g1/100 g sln) |
|---|---|---|
| 6.3 | 6.61 x 10-10 | 7.06 x 10-7 |
| 9.1 | 7.94 x 10-10 | 8.48 x 10-7 |
| 10.8 | 8.83 x 10-10 | 9.43 x 10-7 |
| 13.9 | 1.04 x 10-9 | 1.11 x 10-6 |
| 18.3 | 1.36 x 10-9 | 1.45 x 10-6 |
| 23.1 | 1.79 x 10-9 | 1.91 x 10-6 |
| 25.0 | 1.99 x 10-9 | 2.13 x 10-6 |
| 27.0 | 2.27 x 10-9 | 2.42 x 10-6 |
| 31.1 | 3.01 x 10-9 | 3.21 x 10-6 |