SDS Volume
Volume 37. Hydrocarbons in Water and Seawater, Part I, p 88
Source Publication
Clifford, C. W.; Ind. Eng. Chem. 1921, 13, 631-32.
Conditions:
Room Temp: 21 - 55 °C
Compilers:
Methodology:
A current of air predried by calcium chloride was passed through a sample. The moisture abstracted from the sample by this air was absorbed in calcium chloride tubes. The amount of water was calculated from the weights of these tubes. This method is described in [1].
Sample Information:
- source not specified; 100 percent benzene; dehydrated with metallic sodium; purity not specified.
- not specified.
Measurement Errors:
Ambient temperature: Not specified.
Methodology Citation
System Components:
- Benzene, $\ce{ C6H6 }$; [71-43-2] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | MR2 (g1/100 g2) | $x_{2}$ |
|---|---|---|
| 21.0 | 0.046 | 2.0 x 10-3 |
| 26.6 | 0.055 | 2.4 x 10-3 |
| 42.0 | 0.088 | 3.8 x 10-3 |
| 55.0 | 0.113 | 4.9 x 10-3 |