SDS Volume
Volume 78. Acetonitrile Binary Systems, p 1056
Source Publication
Conditions:
Room Temp: 226 - 284 $\pu{K}$
Compiler:
Methodology:
The synthetic method was used. The freezing-temperature apparatus has been described previously [1] but the temperature -measurement system is new. Temperatures were measured with a Leeds and Northrup platinum resistance thermometer and with a Solartron Model 7081 digital multimeter which has a sensitivity on the $\pu{100 \Omega}$; scale of $\pu{10 \upmu\Omega}$. The multimeter used a 1 mA current for measurements of resistance less than $\pu{100 \Omega}$;. The resistance meter was interfaced to a Hewlett-Packard Model 9845C computer through an IEEE bus. The computer read and stored a resistance measurement every four seconds from which cooling and warming curves of time against temperature could be constructed. The computer could be signaled to record visual melting temperatures during the recording process. The results were continually plotted on a video monitor, recorded on disk, and eventually plotted to provide a permanent record of the time-against-temperature cooling and warming curves.
Sample Information:
- MBC Omnisolv; purified by fractional distillation in a vacuum-jacketed 2 m column packed with glass helices and operated at a reflux ratio of approximately 100; purity 0.9998 mole fractions; MP = -43.87°C.
- Aldrich; reagent grade; purified by fractional distillation in a vacuum-jacketed 2 m column packed with glass helices and operated at a reflux ratio of approximately 100; purity 0.9998 mole fractions; MP = 14.37°C.
Measurement Errors:
Ambient temperature: ±0.05 K.
Methodology Citation
1 Goates, J. R.; Ott, J. B.; Budge, A. H.; J. Phys. Chem. 65, 2162 (1961).
System Components:
- Acetonitrile, $\ce{ C2H3N }$; [75-05-8] NIST WebBook
- 1,1,1-Trichloro-2,2,2-trifluoroethane, $\ce{ C2Cl3F3 }$; [354-58-5] NIST WebBook
Experimental Data
No region of liquid-liquid immiscibility was observed. A full solid-liquid phase diagram in mole fractions over the specified temperature range was reported in the original publication.
A eutectic was reported at 226.14 K (-47.01°C, compiler) at x1 = 0.922 (100 w1 = 72.1, compiler).
| $T$ (°C) | $T$ ($\pu{K}$) | $x_{1}$ | 100w1 |
|---|---|---|---|
| 14.37 | 287.52 | 0.0000 | 0.0 |
| 11.26 | 284.41 | 0.0257 | 0.575 |
| 8.71 | 281.86 | 0.0523 | 1.19 |
| 6.00 | 279.15 | 0.0922 | 2.18 |
| 3.89 | 277.04 | 0.1341 | 3.281 |
| 1.89 | 275.04 | 0.1891 | 4.860 |
| -0.49 | 272.66 | 0.2861 | 8.071 |
| -1.93 | 271.22 | 0.3839 | 12.01 |
| -3.16 | 269.99 | 0.4918 | 17.49 |
| -4.61 | 268.54 | 0.5974 | 24.53 |
| -7.25 | 265.90 | 0.6961 | 33.41 |
| -13.16 | 259.99 | 0.7917 | 45.43 |
| -26.95 | 246.20 | 0.8721 | 59.90 |
| -41.95 | 231.20 | 0.9136 | 69.85 |
| -47.01 | 226.14 | 0.922 | 72.1 |
| -46.45 | 226.70 | 0.9399 | 77.41 |
| -45.79 | 227.36 | 0.9591 | 83.71 |
| -44.83 | 228.32 | 0.9803 | 91.60 |
| -43.87 | 229.28 | 1.0000 | 100.0 |