SDS Volume
Volume 73. Metal and Ammonium Formate Systems, p None
Source Publication
Calame, P.; Z. Phys. Chem. 27U, 401 (1898).
Conditions:
Room Temp: -1.010 - -0.305 °C
Compiler:
Methodology:
Freezing point determinations were made with a Beckmann apparatus having a thermometer graduated in 0.01 °C. The zinc content was determined gravimetrically.
Sample Information:
- Kahlbaum or Merck reagents were used.
Measurement Errors:
Ambient temperature: ±0.01°C.
System Components:
- Zinc formate, $\ce{ Zn(CHO2)2 }$; [557-41-5] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | 100w1 | m1 (mol/kg) a | Phase (s) () |
|---|---|---|---|
| -1.010 | 3.77 | 0.252 | Ice |
| -0.544 | 1.91 | 0.125 | Ice |
| -0.305 | 0.97 | 0.063 | Ice |
(a) These values were calculated by the compiler.