SDS Volume

Volume 72. Nitromethane with Water or Organic Solvents: Ternary and Quaternary Systems, p 1460

Source Publication

Warner, R. K.; Aust. J. Appl. Sci. 4, 427-43 (1953).

Conditions:

Room Temp: 293 $\pu{K}$

Compiler:

V.P. Sazonov

Methodology:

The analytical method was used. The equilibrium procedure for determining the distribution curve has been reported in Warner [1]. To obtain the final point on each curve, the system was saturated with (2) by agitation in the presence of excess solid for periods up to 8 to 10 hrs before sampling. After sampling each phase, the system stood overnight at 20 °C. The following day the system was intermittently agitated for a further 2 hr and the phases analyzed for (2) content to ensure saturation had been reached. The thorium concentration was derminted by evaporation of weighted aliquots, followed by ignition to thorium dioxide.

Sample Information:
  1. Source not specified; purity not specified; distilled.
  2. Source not specified; purity not specified; purified as described in Warner.
  3. Redistilled.
Measurement Errors:

Ambient temperature: control to ±0.1 K.

Methodology Citation

1 Warner, R. K.; Aust. J. Appl. Sci. 3, 156 (1952).

System Components:
  1. Nitromethane, $\ce{ CH3NO2 }$; [75-52-5] NIST WebBook
  2. Uranyl nitrate hexahydrate, $\ce{ UO2(NO3)2(6H2O) }$; [13520-83-7] NIST WebBook
  3. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $T$ ($\pu{K}$) w2
20.0293.2 0.060a
20.0293.2 0.137a
20.0293.2 0.278a
20.0293.2 0.381a
20.0293.2 0.468a
20.0293.2 0.470a
20.0293.2 0.012a
20.0293.2 0.025a
20.0293.2 0.064a
20.0293.2 0.122a
20.0293.2 0.215a
20.0293.2 0.221b

(a) Saturated with ammonium nitrate.

(a) All systems saturated with UO2(NO3)2·6H2O.

(b) All systems saturated with UO2(NO3)2·6H2O.

Download Data   link to XML output link to JSON output link to JSON-LD output