SDS Volume

Volume 37. Hydrocarbons in Water and Seawater, Part I, p 349

Source Publication

Price, L. C.; Am. Assoc. Petrol. Geol. Bull. 1976, 60, 213-44.

Conditions:

Room Temp: 25 - 151.8 °C

Compiler:

F. Kapuku

Methodology:

Room-temperature solubilities were determined by use of screw-cap test tubes. The (1) phase floated on top of (2) and ensured saturation (in two to four days) of the aqueous phase. High-temperature solubility work was carried out in the ovens of the gas chromatograph. The solutions were obtained in 75 mL double ended stainless steel sample cylinders. Modified Micro Linear Valves sealed the bottom of the cylinder and allowed syringe access to the solution during sampling. The sample is then transferred to the gas chromatograph equipped with dual. flame ionization detectors. Many details are given in the paper.

Sample Information:
  1. Phillips Petroleum Company; 99+%.
  2. Distilled.
Measurement Errors:

Ambient temperature: ±1 K
Mass concentration (m/v) (1): range of values given above

System Components:
  1. Hexane, $\ce{ C6H14 }$; [110-54-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) MR1 (mg/kg) $x_{1}$ MR1 (g1/100 g sln)
25.0 9.47 1.98 x 10-69.47 x 10-4
40.1 10.1 2.11 x 10-61.01 x 10-3
55.7 13.2 2.76 x 10-61.32 x 10-3
69.7 15.4 3.22 x 10-61.54 x 10-3
69.7 15.2 3.18 x 10-61.52 x 10-3
99.1 22.4 4.68 x 10-62.24 x 10-3
114.4 29.2 6.10 x 10-62.92 x 10-3
121.3 37.6 7.86 x 10-63.76 x 10-3
137.3 56.9 1.189 x 10-55.69 x 10-3
151.8 106.0 2.22 x 10-50.0106

Download Data   link to XML output link to JSON output link to JSON-LD output