SDS Volume

Volume 37. Hydrocarbons in Water and Seawater, Part I, p 346

Source Publication

Mackay, D.; Shiu, W. Y.; Wolkoff, A. W.; "Water Quality Parameters" Symp. 1973, ASTM Spec. Tech. Publ. 1975, 573, 251-8.

Conditions:

Room Temp: Not specified

Compiler:

M.C. Haulait-Pirson

Methodology:

(1) is partially partitioned into the vapor phase by equilibration of the aqueous sample with helium in a gas syringe, the vapor then being transferred to a gas sampling valve and then to a column of a gas chromatograp equipped with a flame ionization detector. By injecting gas samples from repeated equilibrations it is possible to calculate the amount of (1) in the original sample.

Sample Information:
  1. Not specified.
  2. Not specified.
Measurement Errors:

Mass concentration (m/v) (1): ±10% (compiler)

System Components:
  1. Hexane, $\ce{ C6H14 }$; [110-54-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data

The authors reported the value of 16.2 mg(1)/dm-3 sln for the solubility of hexane in water. With the assumption of a solution density of 1.00 g cm-3, the corresponding mass percent, calculated by the compiler, is 0.00162 g(1)/100 g sln and the corresponding mole fraction, x1, is 3.4 × 10-6.

Download Data   link to XML output link to JSON output link to JSON-LD output