Components:

(1) Carbon dioxide, CO2; [124-38-9] NIST WebBook
(2) Polyimide Ultem, None; [61128-24-3] NIST WebBook

Original Measurements

Okamoto, K. I.; Tanaka, K.; Yokoshi, O.; Hidetoshi, K.; Nakamura, A.; Int. Congress on Membranes (ICOM-87), 9-15, Tokyo (1987).

Variables:

Ambient temperature: 353 K
Pressure: 0 - 3.0 MPa

Prepared by:

Yu.P. Yampol'skii

Method/Apparatus/Procedure:

Equilibrium sorption was measured by the pressure decay method using a dual-volume sorption cell.

Source and Purity of Materials:
  1. Commercial sample of Ultem-1000 (General Electric Co) had a density 1.289 g/cm3, glass transition temperature 488 K, and had an amorphous structure.
Experimental Values:
Dual-mode sorption parameters for carbon dioxide
H (cm3(g) cm-3(s) atm-1) C'H (cm3/cm3) b (atm-1)
5.27 x 10-1 6.1 2.86 x 10-1

Download Data   link to XML output link to JSON output link to JSON-LD output