SDS Volume (4025)

Volume 70. Solubility of Gases in Glassy Polymers, p None

Original Measurements

Okamoto, K. I.; Tanaka, K.; Kita, H.; Nakamura, A.; Kusuki, Y.; J. Poly. Sci.; Part B: Polym. Phys. 27, 1221-1233 (1989).

Variables:

Room Temp: 308 - 383 $\pu{K}$
Pressure: 0 - 3.0 $\pu{MPa}$

Prepared by:

Yu.P. Yampol'skii

Method/Apparatus/Procedure:

Apparatus and procedure of sorption measurement was similar to one described in [1].

Source and Purity of Materials:
  1. Films of the polymer prepared from BPDA and ODA in $p$-chlorphenol were cast from the same solvent, dried (373 K, three hours), immersed in ethanol, dried once more at 443 K for 20 hrs (Sample (1)). Sample (2) was prepared by annealing it at 543 K, three hours. Commercial Upilex-R (Ube Industries) had $T_{\rm{g}}$ = 558 K, $\rho = \pu{1.402 g mL-1}$. Sample (1) had the same $T_{\rm{g}}$.
References

1 Koros, W. J.; Paul, D. R.; J. Polym. Sci., Polym. Phys. Ed., 1976, 14, 1903.

Components:
  1. Carbon dioxide, $\ce{ CO2 }$; [124-38-9] NIST WebBook
  2. Polyimide of BPDA and ODA, [26615-45-2] NIST WebBook
Experimental Data
Dual mode sorption parameters for CO2 in commercial and laboratory samples of BPDA-ODA polyimides
$T$ ($\pu{K}$) $k_{\rm{D}}$ ($\pu{cm3(g) cm-3(s) atm-1}$) $C_{\rm{H}}^{\prime}$ ($\pu{cm3/cm3}$) $b$ ($\pu{atm-1}$)
308 0.59612.00.478
323 0.45610.30.348
353 0.3355.90.252
383 0.2543.40.162
323 0.60917.90.392
353 0.44910.60.236
353 0.31611.00.167
383 0.3277.00.140
353 0.2674.70.216

Download Data   link to XML output link to JSON output link to JSON-LD output