Components:

(1) Carbon dioxide, CO2; [124-38-9] NIST WebBook
(2) Polyimide of BPDA and ODA (Upilex-R), None; [26615-45-2] NIST WebBook

Original Measurements

Tanaka, K.; Kita, H.; Okamoto, K.; Japan - US Polymer Symposium, p. 249-250 (1985).

Variables:

Ambient temperature: 323 - 383 K
Pressure: 0 - 2.0 MPa

Prepared by:

Yu.P. Yampol'skii

Method/Apparatus/Procedure:

Sorption was measured by the pressure decay method. The same isotherms were obtained for 'as received' samples and the specimens preliminary exposed to 50 atm of carbon dioxide at 323 K for 24 h.

Source and Purity of Materials:
  1. Polyimide Upilex R (Ube Industries) had the glass transition temperature 558 K.
Experimental Values:
Dual mode sorption parameters*
T (K) H (cm3(g) cm-3(s) atm-1) C'H (cm3/cm3) b (atm-1)
323.0 5.0 x 10-1 8.6 4.4 x 10-1
353.0 3.5 x 10-1 5.0 3.0 x 10-1
383.0 2.5 x 10-1 3.0 1.9 x 10-1

(*) Read by the compiler from the plot.

Download Data   link to XML output link to JSON output link to JSON-LD output