SDS Volume

Volume 70. Solubility of Gases in Glassy Polymers, p None

Source Publication

Frimpong, S.; Plank, C. A.; Laukhauf, W. L. S.; Chem. Eng. J. 42, 25 (1989).

Conditions:

Room Temp: 283.2 - 343.2 $\pu{K}$
Pressure: 0 - 100 $\pu{kPa}$

Compiler:

Yu.P. Yampol'skii

Methodology:

A McBain quartz spring balance was employed for sorption measurement. The apparatus is described in [2].

Sample Information:
  1. PC (Lexan 101): General Electric Co., $T_{\rm{g}}$ = 421 K (DSC), MP = 496.8 K.
Measurement Errors:

Ambient temperature: Relative precision in T: ±0.1 K.

Methodology Citations

1 Plank, C. A.; Laukauf, W. L. S.; Ranade, G. R.; J. Appl. Polym. Sci. 30, 2695 (1985).
2 Ranade, O. R.; Nadgir, V. M.; Plank, C. A.; Laukhuf, W. L. S.; J. Appl. Polym. Sci. 28, 201 (1983).

System Components:
  1. Copoly(pyromellitic dianhydride-oxydianiline) (PMDA-ODA), [25036-53-7] NIST WebBook
  2. Polycarbonate (PC), $\ce{ (C16H18O5)n }$; [25037-45-0] NIST WebBook
Experimental Data

The experiment data for 298.2 and 313.2 K were correlated by the equation:

C=123.212 exp(1.0772 × 10-3(RT/cal mol-1)(ln(p/atm)) + (2355/((T/K)-33))-10.24)]
based on adsorption potential theory in Ref. 1.

$T$ ($\pu{K}$) $k_{\rm{H}}$ ($\pu{cm3(g) cm-3(s) atm-1}$) $C_{\rm{H}}^{\prime}$ ($\pu{cm3/cm3}$) $b$ ($\pu{atm-1}$)
283.2 61.6622.4519.39
298.2 40.2613.9316.33
313.2 26.279.5215.57
343.2 11.724.0812.13
Solubility graph

None

Download Data   link to XML output link to JSON output link to JSON-LD output