SDS Volume

Volume 69. Ternary Alcohol-Hydrocarbon-Water Systems, p None

Source Publication

Vorobeva, A. I.; Karapetyants, M. Kh.; Zh. Fiz. Khim. 41, 1984-9 (1967).

Conditions:

Room Temp: 298 $\pu{K}$

Compiler:

A. Skrzecz

Methodology:

The experimental methods were described in [1]. Water impurities in alcohol were taken into account in the measurements. Critical point of liquid-liquid equilibrium was obtained graphically by the method reported in [2].

Sample Information:
  1. Source and method of preparation were reported in [1].
  2. Source not specified; pure grade; distilled; water concentration was analyzed by the Karl Fischer method.
  3. Doubly distilled.
Measurement Errors:

Ambient temperature: Not specified.
Mass concentration (m/v) (1): Not reported.

Methodology Citations

1 Vorobeva, A. I.; Karapetyants, M. Kh.; Zh. Fiz. Khim. 40, 3018 (1966).
2 Zilberman,E. N.; Zh. Fiz. Khim. 26, 1458 (1952).

System Components:
  1. 2-Propanol, $\ce{ C3H8O }$; [67-63-0] NIST WebBook
  2. Heptane, $\ce{ C7H16 }$; [142-82-5] NIST WebBook
  3. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $T$ ($\pu{K}$) w1 w2 $x_{1}$ $x_{2}$
25298.2 0.0000.999 0.00000.9945
25298.2 0.1600.830 0.23150.7202
25298.2 0.2190.760 0.29400.6119
25298.2 0.3450.604 0.39320.4129
25298.2 0.4050.524 0.42360.3287
25298.2 0.4750.425 0.44670.2397
25298.2 0.5460.322 0.46290.1637
25298.2 0.5840.255 0.45840.1200
25298.2 0.6190.148 0.41680.0598
25298.2 0.6200.136 0.40910.0538
25298.2 0.6040.080 0.35400.0281
25298.2 0.5690.050 0.30430.0160
25298.2 0.5140.027 0.24947.9 x 10-3
25298.2 0.4108 x 10-3 0.17402.0 x 10-3

(a) Critical point obtained graphically by the authors.

Download Data   link to XML output link to JSON output link to JSON-LD output