Components:
(1) 1,2-Dichloropropane,
C3H6Cl2; [78-87-5]
NIST WebBook
(2) Water,
H2O; [7732-18-5]
NIST WebBook
Original Measurements
Howe, G. B.; Mullins, M. E.; Rogers, T. N.; AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).
Variables:
Ambient temperature: 283 - 303 K
Prepared by:
Method/Apparatus/Procedure:
250 cm3 bottles were filled with distilled deionized water and sealed. Measured volumes of the 1,2-dichloropropane were injected into the bottles through each bottle septum using a microliter syringe. The solute was in excess of the anticipated solubility limit. The bottles were shaken for 1 hour with a wristaction shaker and allowed to equilibrate for about three weeks. Samples were then injected into a gas chromatograph equipped with a Carbopack column and a FID detector. The GC responses were compared with calibration plots to establish concentrations.
Source and Purity of Materials:
- Probably a commercial reagent, at least 99% pure. Used as received.
- Distilled deionized.
Estimated Errors:
Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.
Experimental Values:
| T (°C) | w1 | 100w1a | x1 |
|---|---|---|---|
| 10.0 | 2.062 x 10-3 | 2.062 x 10-1 | 3.294 x 10-4 |
| 20.0 | 2.030 x 10-3 | 2.030 x 10-1 | 3.242 x 10-4 |
| 30.0 | 1.867 x 10-3 | 1.867 x 10-1 | 2.982 x 10-4 |