SDS Volume (3602)

Volume 68. Halogenated Aliphatic Compounds C3-C14 with Water, p None

Original Measurements

Howe, G. B.; Mullins, M. E.; Rogers, T. N.; AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).

Variables:

Room Temp: 283 - 303 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

250 mL bottles were filled with distilled deionized water and sealed. Measured volumes of the 1,2-dichloropropane were injected into the bottles through each bottle septum using a microliter syringe. The solute was in excess of the anticipated solubility limit. The bottles were shaken for one hour with a wristaction shaker and allowed to equilibrate for about three weeks. Samples were then injected into a gas chromatograph equipped with a Carbopack column and a FID detector. The GC responses were compared with calibration plots to establish concentrations.

Source and Purity of Materials:
  1. Probably a commercial reagent, at least 99% pure. Used as received.
  2. Distilled deionized.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.

Components:
  1. 1,2-Dichloropropane, $\ce{ C3H6Cl2 }$; [78-87-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) w1 100w1 $x_{1}$
10 2.062 x 10-3 0.20623.294 x 10-4
20 2.030 x 10-3 0.20303.242 x 10-4
30 1.867 x 10-3 0.18672.982 x 10-4

Download Data   link to XML output link to JSON output link to JSON-LD output