SDS Volume
Volume 68. Halogenated Aliphatic Compounds C3-C14 with Water, p None
Source Publication
Conditions:
Room Temp: 298 $\pu{K}$
Compiler:
Methodology:
A saturated aqueous solution was prepared by passing of water through a column which was packed with glass beads coated with 1-iodoheptane. The saturated solution was then pumped through an extractor column and 1- iodoheptane was extracted directly into an analytical column. The samples were analyzed with a liquid chromatograph equipped with both an UV absorbance and a fluorescence detector with excitation filters. The peak area was established using a Hewlett-Packard recorder.
Sample Information:
- Eastman Kodak Company. Commercial quality, used as received.
- Double distilled.
Measurement Errors:
Ambient temperature: ±1 K (compiler).
Mass concentration (m/v) (1): Not specified.
System Components:
- 1-Iodoheptane, $\ce{ C7H15I }$; [4282-40-0] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $C_{1}$ (mol/m3) | 100w1 | $x_{1}$ |
|---|---|---|---|
| 25 | 0.0155 | 3.50 x 10-4 | 2.80 x 10-7 |