SDS Volume

Volume 68. Halogenated Aliphatic Compounds C3-C14 with Water, p None

Source Publication

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Conditions:

Room Temp: 274 - 296 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

A 5 μL 1-chlorohexane sample was injected into a 2.3 L equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The 1-chlorohexane content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Sample Information:
  1. Source and purity not given.
  2. distilled.
Measurement Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±5.8%.

System Components:
  1. 1-Chlorohexane, $\ce{ C6H13C1 }$; [544-10-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 a $x_{1}$ a DL
1 3.687 x 10-35.507 x 10-6399.5
3 4.946 x 10-37.387 x 10-6365.5
12.4 5.645 x 10-38.432 x 10-6668.3
12.5 5.248 x 10-37.839 x 10-6728.4
17.9 6.187 x 10-39.241 x 10-6873.2
19.1 5.929 x 10-38.855 x 10-6969.7
22.7 6.237 x 10-39.316 x 10-61.1614 x 103
23.0 5.783 x 10-38.638 x 10-61.2677 x 103

(a) Gas-liquid system analysis parameter, from calibration measurements.