SDS Volume (3488)

Volume 68. Halogenated Aliphatic Compounds C3-C14 with Water, p None

Original Measurements

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Variables:

Room Temp: 274 - 296 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 5 μL 1,5-dichloropentane sample was in-jected into a 2.3 L equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The 1,5-dichloropentane content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Source and Purity of Materials:
  1. Source and purity not given.
  2. distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±12.9%.

Components:
  1. 1,5-Dichloropentane, $\ce{ C5H10Cl2 }$; [628-76-2] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
1.0 0.011701.4949 x 10-516.36
3.0 9.763 x 10-31.2472 x 10-523.10
12.04 0.022142.8282 x 10-521.41
12.5 0.016422.0974 x 10-528.87
17.9 0.026353.3668 x 10-526.96
19.1 0.020802.6579 x 10-536.69
22.7 0.012321.5732 x 10-579.33

(a) Gas-liquid system analysis parameter, from calibration measurements.

(b) These values were calculated by the compiler.

Download Data   link to XML output link to JSON output link to JSON-LD output