SDS Volume
Volume 68. Halogenated Aliphatic Compounds C3-C14 with Water, p None
Source Publication
Conditions:
Room Temp: 298 $\pu{K}$
Compiler:
Methodology:
A saturated aqueous solution was prepared by passing of water through a column which was packed with glass beads coated with 1-chlorobutane. The saturated solution was then pumped through an extractor column and 1- chlorobutane was extracted directly into an analytical column. The samples were analyzed with a liquid chromatograph equipped with both an UV absorbance and a fluorescence detector with excitation filters. The peak area was established using a Hewlett-Packard recorder.
Sample Information:
- Eastman Kodak Company, commercial quality, used as received.
- Double distilled.
Measurement Errors:
Ambient temperature: ±1 K (compiler).
Mass concentration (m/v) (1): Not specified.
System Components:
- 1-Chlorobutane, $\ce{ C4H9C1 }$; [109-69-3] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $C_{1}$ (mol/m3) | 100w1 a | $x_{1}$ a |
|---|---|---|---|
| 25 | 9.43 | 0.0875 | 1.70 x 10-4 |