SDS Volume (3450)

Volume 68. Halogenated Aliphatic Compounds C3-C14 with Water, p None

Original Measurements

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Variables:

Room Temp: 287 - 298 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 5 μL 1,4-Dichlorobutane sample was injected into a 2.3 L equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The 1,4-Dichlorobutane content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Source and Purity of Materials:
  1. Source and purity not given.
  2. distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±6.1%.

Components:
  1. 1,4-Dichlorobutane, $\ce{ C4H8C12 }$; [110-56-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
13.5 0.12011.705 x 10-415.27
15.7 0.10441.482 x 10-420.05
17.1 0.10821.536 x 10-421.35
22.0 0.12831.822 x 10-424.76
24.9 0.15742.236 x 10-426.61

(a) Gas-liquid system analysis parameter, from calibration measurements.

Download Data   link to XML output link to JSON output link to JSON-LD output