SDS Volume (3420)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 454

Original Measurements

Eberius, E.; Wasserbestimmung mit Karl-Fischer-Losung (Verlag, GMBH, Weinheim, 1954), p. 67.

Variables:

Room Temp: 293 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

50 g trichloroethene was shaken with pure water in a 100 mL Erlenmeyer flask. When equilibrium was attained and the two phases separated, the organic phase was analyzed for water using the Karl Fischer titration method. Five determinations were performed.

Source and Purity of Materials:
  1. Distilled.
  2. Source and purity not given.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): See table above.

Components:
  1. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
  2. Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ $mol_{1}/\pu{100 g}$ (mol/g)
20 0.011 8.02 x 10-46.10 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output