SDS Volume

Volume 67. Halogenated Ethanes and Ethenes with Water, p 453

Source Publication

Powell, J. F.; Br. J. Industr. Med. 4, 233 (1947).

Conditions:

Room Temp: 293 - 310 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

The trichloroethene and air mixtures were prepared in gas cylinders under pressure. An Oxford vaporizer was used to produce a high concentration of trichloroethene. Water was equilibrated with the gas mixture by a simple bubbling technique. The saturated aqueous solution was treated with pyridiene and $\ce{HCl}$ solution to generate a yellow color which was measured spectrophotometrically using a filter transmitting at 430 m. u.

Sample Information:
  1. Source and purity not given.
  2. Distilled.
Measurement Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±3.0%.

System Components:
  1. Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 a $x_{1}$ $L$
20 0.1261.72 x 10-43.0
37 0.1371.89 x 10-41.6

Download Data   link to XML output link to JSON output link to JSON-LD output