SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 450
Source Publication
Wright, W. H.; Schaffer, J. M.; Am. J. Hygiene 16, 325 (1932).
Conditions:
Room Temp: 298 $\pu{K}$
Compiler:
Methodology:
The solubility was determined by mixing definite quantities of trichloroethene with a large volume of water and measuring the volume of the undissolved trichloroethene.
Sample Information:
- Commercial grade, further purified by washing with $\ce{NaHCO3}$ solution and then redistilled.
- Distilled.
Measurement Errors:
Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.
System Components:
- Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $x_{1}$ | S2:1 ($\pu{cm3/g}$) | 100w1 a |
|---|---|---|---|
| 25 | 2.50 x 10-4 | 5.5E+2 | 0.182 |