SDS Volume (3406)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 409

Original Measurements

Howe, G. B.; Mullins, M. E.; Rogers, T. N.; AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).

Variables:

Room Temp: 283 - 303 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

250 mL bottles were filled with distilled and deionized water and sealed. Measured volumes of 1,1,2-trichloro-1,2,2-trifluoroethane were injected into the bottles through each bottle septum using a microliter syringe. The solute was in excess of the anticipated solubility limit. The bottles were shaken for one hour with a wrist-action shaker and allowed to equilibrate for about three weeks. Samples were then injected into a gas chromatograph equipped with a Carbopack column and a FID detector. The gas chromatography (GC) responses were compared with calibration response plots to establish concentrations.

Source and Purity of Materials:
  1. Probably a commercial reagent at least 99% purity; used as received.
  2. Distilled and deionized.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.

Components:
  1. 1,1,2-Trichloro-1,2,2-trifluoroethane, $\ce{ C2Cl3F3 }$; [76-13-1] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) w1 100w1 $x_{1}$
10 3.8 x 10-5 3.8 x 10-33.65 x 10-6
20 2.7 x 10-5 2.7 x 10-32.60 x 10-6
30 1.4 x 10-5 1.4 x 10-31.35 x 10-6