SDS Volume (3401)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 444

Original Measurements

Halliday, M. M.; MacDonald, I.; MacGregor, M. H. G.; Br. J. Anaesth. 49, 413 (1977).

Variables:

Room Temp: 310 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A steady flow of anaesthetic vapor was bubbled through water, allowing 45 minutes for equilibration. The concentration in the gas mixture was in the range 1-3 % (v/v) 2-bromo-2-chloro-1,1,1-tri-fluoroethane. A Riken 18A refractometer provided accurate estimations of the gaseous concentrations of 2-bromo-2-chloro-1,1,1-trifluoroethane. Five samples of aqueous solutions were analyzed by gas chromatography. The chromatograph was equipped with a flame ionization detector and apotentiometric recorder.

Source and Purity of Materials:
  1. ICI Pharmaceuticals, used as received.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±0.01 SEM.

Components:
  1. 2-Bromo-2-chloro-1,1,1-trifluoroethane, $\ce{ C2HBrClF3 }$; [151-67-7] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ $L$
36.85 0.3893.56 x 10-40.80

Download Data   link to XML output link to JSON output link to JSON-LD output