SDS Volume (3326)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 604

Original Measurements

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Variables:

Room Temp: 274 - 300 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 5 μL 1,2-dichloroethane sample was injected into a 2.3 L equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The 1,2-dichloroethane content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±5.0%.

Components:
  1. 1,2-Dichloroethane, $\ce{ C2H4Cl2 }$; [107-06-2] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
1.0 0.52569.610 x 10-430.62
1.3 0.53639.807 x 10-430.89
11.0 0.60321.1035 x 10-346.56
21.0 0.68011.2451 x 10-368.89
22.0 0.64261.1761 x 10-376.59
27.2 0.65481.1985 x 10-395.46

(a) Gas-liquid system analysis parameter, from calibration measurements.

Download Data   link to XML output link to JSON output link to JSON-LD output