SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 424
Source Publication
Lincoff, A. H.; Gossett, J. M.; in Gas Transfer at Water Surfaces by Brutsaert, W.; Jirka, G. H.; Eds.; D. Reidel Publ. Co.; Dordrecht, 1984, p. 17-25.
Conditions:
Room Temp: 293 $\pu{K}$
Compiler:
Methodology:
Henry's law constants were measured by EPICS and Batch Air Stripping Methods. The Equilibrium Partitioning in the Closed Systems technique compares the GC peak heights upon direct injection of headspace samples. In the Batch Air Stripping Method, equal volume samples were placed in serum bottles and the equilibrated headspaces contained concentrations proportional to original concentrations in the aqueous samples. Full equilibrium was achieved in a few hours.
Sample Information:
- Source and purity not given.
- Distilled.
Measurement Errors:
Ambient temperature: 0.1 K.
Mass concentration (m/v) (1): ±5 - 10%.
System Components:
- Tetrachloroethene, $\ce{ C2Cl4 }$; [127-18-4] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
EPICS Method: loge H=13.12-5119/(T/K)
Batch air stripping method: loge H=11.32-4622/(T/K)
| $T$ (°C) | 100w1 a | $x_{1}$ a | $k_{\rm{H}}$ (m3 atm mol-1) |
|---|---|---|---|
| 20 | 0.02379 | 2.585 x 10-5 | 0.0130 |