SDS Volume

Volume 67. Halogenated Ethanes and Ethenes with Water, p 424

Source Publication

Mackay, D.; Shiu, W.; Bobra, A.; Billington, J.; Chau, E.; Volatilization of Organic Pollutants from Water, U.S. EPA Report 600/3-82-019, Washington, DC, 1982, (NTIS PB82230939).

Conditions:

Room Temp: 293 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

An aqueous solution with an excess amount of tetrachloroethene was stirred for one day before being introduced into a one liter glass vessel. Nitrogen entered at the bottom of the vessel through a sintered glass disk. The exit gas flow rate was measured by a soap bubble flow meter. The concentration of tetrachloroethene in water was determined by gas chromatography. The GC was equipped with both a dual flame ionization detector and an electron capture detector.

Sample Information:
  1. Source and purity not given.
  2. Doubly distilled.
Measurement Errors:

Ambient temperature: ±1.0 K.
Mass concentration (m/v) (1): Not specified.

System Components:
  1. Tetrachloroethene, $\ce{ C2Cl4 }$; [127-18-4] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $\rho, (20^{\circ}C)$ (g/L) 100w1 a $x_{1}$ a
200.400 0.04004.347 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output