SDS Volume (3266)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 575

Original Measurements

Howe, G. B.; Mullins, M. E.; Rogers, T. N.; AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).

Variables:

Room Temp: 283 - 303 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

250 mL bottles were filled with distilled deionized water and sealed. Measured volumes of 1,1-dichloroethane were injected into the bottles through each bottle septum using a microliter syringe. The solute was in excess of the anticipated solubility limit. The bottles were shaken for one hour with a wrist-action shaker and allowed to equilibrate for about three weeks. Samples were then injected into a gas chromatograph equipped with a Carbopack column and a FID detector. The GC responses were compared with calibration plots to establish concentrations.

Source and Purity of Materials:
  1. Probable a commercial reagent at least 99% pure, used as received.
  2. Distilled and deionized.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.

Components:
  1. 1,1-Dichloroethane, $\ce{ C2H4C12 }$; [75-34-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) MR1 (g1/g2) 100w1 $x_{1}$
10 7.435 x 10-3 0.74351.3613 x 10-3
20 7.137 x 10-3 0.71371.3069 x 10-3
30 6.13 x 10-3 0.61301.1216 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output