SDS Volume (3257)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 571

Original Measurements

Sato, A.; Nakijima, T.; Arch. Envir. Health 1979, 34, 69-75.

Variables:

Room Temp: 310 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 1,1-dichloroethane vapor sample was equilibrated in an airtight vial between water and the overlying air. When equilibrium was reached, a portion of the equilibrated air in the vessel was withdrawn using an airtight syringe and then injected into a gas chromatograph and analyzed. The signal peak height on the chromatogram was used to calculate the partition coefficient.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler)
Mass concentration (m/v) (1): ±0.6 std. dev.

Components:
  1. 1,1-Dichloroethane, $\ce{ C2H4C12 }$; [75-34-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ $k_{\rm{D}}$
37 0.5129.36 x 10-42.7

(a) Gas-liquid chromatographic parameter, from instrument calibration.

Download Data   link to XML output link to JSON output link to JSON-LD output