SDS Volume (3245)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 421

Original Measurements

Coca, J.; Diaz, R. M.; Pazos, C.; Fluid Phase Equilib. 1980, 4, 123-136.

Variables:

Room Temp: 298 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

Saturation was determined by titration. The measurement was performed in an Erlenmeyer flask by adding tetrachloroethene to water until a permanent turbidity was observed. The flask was immersed in a water bath thermostat while maintaining a constant agitation through the use of a magnetic stirrer.

Source and Purity of Materials:
  1. Fluka laboratory grade reagent, further purified by distillation; middle fraction used.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.05 K.
Mass concentration (m/v) (1): Not specified.

Components:
  1. Tetrachloroethene, $\ce{ C2Cl4 }$; [127-18-4] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) w1 w2 $x_{1}$ $x_{2}$
25 2.0 x 10-41.0 2.17 x 10-59.20 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output