SDS Volume

Volume 67. Halogenated Ethanes and Ethenes with Water, p 545

Source Publication

Newsham, D. M. T.; Measurement and Correlation of Thermodynamic Data for Chlorinated Hydrocarbons, UMIST, Manchester (January. 1981).

Conditions:

Room Temp: 286 - 323 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

Samples were equilibrated for at least ten days in waterbath thermostat. The concentration of 1,1,2-trichloroethane in water was determined using a Perkin-Elmer model 900 gas chromatograph equipped with a flame ionization detector and an automatic digital integrator. A helium carrier gas and a Poropack QS column were used for the chromatographic analyses.

Sample Information:
  1. Source not given, contained less than 0.1% dissolved material.
  2. Distilled (compiler).
Measurement Errors:

Ambient temperature: ±0.1 K.
Mass concentration (m/v) (1): ±1%.

System Components:
  1. 1,1,2-Trichloroethane, $\ce{ C2H3Cl3 }$; [79-00-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $x_{1}$ 100w1 a $mol_{1}/\pu{100 g}$ (mol/g) a
12.5 5.86 x 10-4 4.32 x 10-33.24 x 10-5
14.0 5.73 x 10-4 4.23 x 10-33.17 x 10-5
21.0 5.77 x 10-4 4.26 x 10-33.19 x 10-5
21.6 5.87 x 10-4 4.33 x 10-33.25 x 10-5
25.0 5.83 x 10-4 4.30 x 10-33.22 x 10-5
30.0 6.19 x 10-4 4.56 x 10-33.42 x 10-5
35.0 6.00 x 10-4 4.42 x 10-33.31 x 10-5
40.0 6.46 x 10-4 4.76 x 10-33.57 x 10-5
50 7.58 x 10-4 5.58 x 10-34.18 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output