SDS Volume (3202)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 544

Original Measurements

Veith, G. D.; Macek, K. J.; Petrucelli, S. R.; Carroll, J.; Proc. 3rd Ann. Symp. on Aquatic Toxicology, ASTM Publ. 707, Philadelphia, 1980, p. 116-29.

Variables:

Room Temp: 293 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

An excess of 1,1,2-trichloroethane was added to 10 mL distilled water in a 50 mL flask. The mixture was magnetically stirred in a constant temperature water bath. The equilibrium mixture was analyzed by using radioactive techniques. The $\ce{^{14}C}$ activity of the water samples was measured in a liquid scintillation spectrometer by recording the number of counts per minute.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±1 K.
Mass concentration (m/v) (1): Not specified.

Components:
  1. 1,1,2-Trichloroethane, $\ce{ C2H3Cl3 }$; [79-00-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $C_{1}$ (mol/m3) 100w1 $x_{1}$
20 0.0112 0.1492.02 x 10-4

Download Data   link to XML output link to JSON output link to JSON-LD output