SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 541
Source Publication
Treybal, R. E.; Weber, L. D.; Daley, J. F.; Ind. Eng. Chem. 38, 817-21 (1946).
Conditions:
Room Temp: 298 $\pu{K}$
Compiler:
Methodology:
1,1,2-Trichloroethane, while held in a water-bath thermostat, was titrated with water until the appearance of a slight turbidity, which indicated the limiting solubility concentration. At the same time, the refractive index and density of the solutions were determined. Similar measurements were made by titration of water with 1,1,2-trichloroethane.
Sample Information:
- Carbide and Carbon Chemicals Co., redistilled before use, BP = 113.3°C.
- Distilled.
Measurement Errors:
Ambient temperature: ±0.1 K.
Mass concentration (m/v) (1): Not specified.
System Components:
- 1,1,2-Trichloroethane, $\ce{ C2H3Cl3 }$; [79-00-5] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | 100w1 | 100w2 | $x_{1}$ | $x_{2}$ |
|---|---|---|---|---|
| 25.0 | 0.44 | 0.11 | 5.96 x 10-4 | 8.09 x 10-3 |