SDS Volume

Volume 67. Halogenated Ethanes and Ethenes with Water, p 541

Source Publication

Treybal, R. E.; Weber, L. D.; Daley, J. F.; Ind. Eng. Chem. 38, 817-21 (1946).

Conditions:

Room Temp: 298 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

1,1,2-Trichloroethane, while held in a water-bath thermostat, was titrated with water until the appearance of a slight turbidity, which indicated the limiting solubility concentration. At the same time, the refractive index and density of the solutions were determined. Similar measurements were made by titration of water with 1,1,2-trichloroethane.

Sample Information:
  1. Carbide and Carbon Chemicals Co., redistilled before use, BP = 113.3°C.
  2. Distilled.
Measurement Errors:

Ambient temperature: ±0.1 K.
Mass concentration (m/v) (1): Not specified.

System Components:
  1. 1,1,2-Trichloroethane, $\ce{ C2H3Cl3 }$; [79-00-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 100w2 $x_{1}$ $x_{2}$
25.0 0.440.11 5.96 x 10-48.09 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output