SDS Volume (3179)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 533

Original Measurements

McNally, M. E.; Grob, R. L.; J. Chromatogr. A 1984, 284, 105-16.

Variables:

Room Temp: 303 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

Standard 1,1,1-trichloroethane solutions of increasing concentration were prepared in volumetric flasks as described elsewhere [1]. The aqueous organic liquid phase was 25 mL and the vapor phase above the mixture was 35 mL. The system was allowed equilibrium in a constant temperature bath and then a sample was injected into the gas chromatograph. Values reported are an average of at least 5 measurements.

Source and Purity of Materials:
  1. Chemical Service, West Chester, PA., USA., purest grade available.
  2. Distilled and run through two Barnstead purification cartridges before use.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±5.17% std. dev.

References

1 McNally, M. E.; Grob, R. L.; J. Chromatogr. A 1983, 260, 23-32.

Components:
  1. 1,1,1-Trichloroethane, $\ce{ C2H3Cl3 }$; [71-55-6] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) ρ (g/L) 100w1 $x_{1}$
300.4798 0.048166.506 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output