Components:
(1) 1,1,2,2-Tetrachloroethane,
C2H2C14; [79-34-5]
NIST WebBook
(2) Water,
H2O; [7732-18-5]
NIST WebBook
Original Measurements
Howe, G. B.; Mullins, M. E.; Rogers, T. N.; AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).
Variables:
Ambient temperature: 283 - 303 K
Prepared by:
Method/Apparatus/Procedure:
250 cm3 bottles were filled with distilled, deionized water and sealed. Measured volumes of 1,1,2,2-tetrachloroethane were injected into the bottles through each bottle septum using a microliter syringe. The solute was in excess of the anticipated solubility limit. The bottles were shaken for 1 hour with a wrist-action shaker and allowed to equilibrate for about three weeks. Samples were then injected into a gas chromatograph equipped with a Carbo-pack column and a FID detector.The GC responses were compared with calibration plots to establish concentrations.
Source and Purity of Materials:
- Probably a commercial reagent, at least 99% pure, used as received.
- Distilled and deionized.
Estimated Errors:
Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.
Experimental Values:
| T (°C) | MR1 (g1/g2) | 100w1a | x1 |
|---|---|---|---|
| 10.0 | 2.588 x 10-3 | 2.588 x 10-1 | 2.7841 x 10-4 |
| 20.0 | 2.56 x 10-3 | 2.526 x 10-1 | 2.7173 x 10-2 |
| 30.0 | 2.131 x 10-3 | 2.131 x 10-1 | 2.2916 x 10-2 |