SDS Volume (3137)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 513

Original Measurements

Schwarz, F. P.; Anal. Chem. 1980, 52, 10-15.

Variables:

Room Temp: 297 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

The aqueous solubility was determined by elution chromatography. The solute columns (3 mm o.d., 2 mm i.d., and 40 cm long) were filled with Chromosorb P. The analysis consisted of removing a segment of the column packing and placing it into a test tube containing n-octane. Then, samples were injected into a gas chromatograph for analysis. The average deviations were calculated from several measurements on different samples.

Source and Purity of Materials:
  1. Commercial reagent of spectral grade, used as received.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±1.5 K.
Mass concentration (m/v) (1): ±3.0% std. dev.

Components:
  1. 1,1,2,2-Tetrachloroethane, $\ce{ C2H2C14 }$; [79-34-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ $mol_{1}/\pu{100 g}$ (mol/g)
23.5 0.296 3.18 x 10-41.76 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output