Components:

(1) cis-1,2-Dichloroethene, C2H2Cl2; [156-59-2] NIST WebBook
(2) Water, H2O; [7732-18-5] NIST WebBook

Original Measurements

Howe, G. B.; Mullins, M. E.; Rogers, T. N.; AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).

Variables:

Ambient temperature: 283 - 303 K

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

250 cm3 bottles were filled with distilled and deionized water and sealed. A measured volume of cis-1,2-dichloroethene was injected into the bottles through each septum using a microliter syringe. The cis-1,2-dichloroethene was in excess of the anticipated solubility limit. The bottles were shaken for 1 hour with a wrist-action shaker and allowed to equilibrate for about 3 weeks. Samples were then injected into a gas chromatograph equipped with a Carbopac Column and a FIDdetector. The GC response was compared with calibration plots.

Source and Purity of Materials:
  1. Probably a commercial reagent at least 99% pure, used as received.
  2. Distilled and deionized.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.

Experimental Values:
T (°C) MR1 (g1/g2) 100w1a x1a
10.0 1.52 x 10-4 1.52 x 10-2 2.825 x 10-5
20.0 2.73 x 10-4 2.73 x 10-2 5.075 x 10-5
30.0 1.76 x 10-4 1.76 x 10-2 3.271 x 10-5

Download Data   link to XML output link to JSON output link to JSON-LD output