Components:

(1) 1,1-Dichloroethene, C2H2Cl2; [75-35-4] NIST WebBook
(2) Water, H2O; [7732-18-5] NIST WebBook

Original Measurements

McNally, M. E.; Grob, R. L.; J. Chromatogr. A 1984, 284, 105-16.

Variables:

Ambient temperature: 303 K

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

Standard 1,1-dichloroethene solutions of increasing concentration were prepared in volumetric flasks as described elsewhere.1 The aqueous organic liquid phase was 25 cm3 and the vapor phase above the mixture was 35 cm3. The system was allowed to reach equilibrium in a constant temperature bath and then a sample was injected into the gas chromatograph for analysis. Values reported are an average of at least five measurements.

Source and Purity of Materials:
  1. Chemical Service, West Chester, PA., USA., purest grade available.
  2. Distilled and run through two Barnstead purification cartridges.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±3.67% std. dev.

References

1 McNally, M. E.; Grob, R. L.; J. Chromatogr. A 1983, 260, 23-32.

Experimental Values:
T (°C) 100w1a x1
30.0 2.237 x 10-1 4.165 x 10-4

Download Data   link to XML output link to JSON output link to JSON-LD output