SDS Volume (3085)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 487

Original Measurements

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Variables:

Room Temp: 276 - 299 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 5 µL 1,1-dichloroethene sample was injected into a 2.3 L equilibration cell containing distilled water. After the liquid sample was shaken vigorously for about 5 minutes, its homogeneity was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The 1,1-dichloroethene content was extracted and measured using a gas chromatograph which was equipped with a dual flame ionization detector.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±14.0%.

Components:
  1. 1,1-Dichloroethene, $\ce{ C2H2Cl2 }$; [75-35-4] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
2.5 0.31745.9132 x 10-4533.5
7.0 0.26474.9299 x 10-4780.1
12.9 0.22884.2589 x 10-41.1618 x 103
18.0 0.24294.5227 x 10-41.3364 x 103
19.5 0.19653.6572 x 10-41.7520 x 103
24.3 0.24254.5158 x 10-41.7145 x 103
26.1 0.20473.8113 x 10-42.1468 x 103

(a) Gas-liquid system analysis parameter, from calibration measurements.

Download Data   link to XML output link to JSON output link to JSON-LD output