SDS Volume

Volume 67. Halogenated Ethanes and Ethenes with Water, p 477

Source Publication

Hutchinson, C. A.; Lyon, A. M.; Columbia University Report A-745, July 1, 1943.

Conditions:

Room Temp: 298 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

A mixture of 1 to 15 volume ratio of heavy water and pentachloroethane was introduced into an equilibration flask and then lowered into a waterbath thermostat. The assembly was shaken mechanically for about 90 minutes at constant temperature. The amount of heavy water in the organic phase was determined by a modified Karl Fischer titration method. The determination was done in triplicate. This procedure description was taken from a secondary source [1].The original university report is no longer available.

Sample Information:
  1. Source and purity not given.
  2. Source not given. Purified and dried before use.
Measurement Errors:

Ambient temperature: ±0.05 K.
Mass concentration (m/v) (1): ±1.0 × 10-5 av. dev.

Methodology Citation

1 Eidinoff, M. L.; Joris, G. G.; Taylor, H. S.; Urey, H. C.; eds., Production of Heavy Water (McGraw_Hill, New York, 1955), p. 129.

System Components:
  1. Water-d2, $\ce{ D2O }$; [7789-20-0] NIST WebBook
  2. Pentachloroethane, $\ce{ C2HCl5 }$; [76-01-7] NIST WebBook
Experimental Data
$T$ (°C) $mol_{1}/\pu{100 g}$ (mol/g) 100w1 a $x_{1}$ a
25 1.63 x 10-3 0.03263.28 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output