SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 472
Source Publication
Wright, W. H.; Schaffer, J. M.; Am. J. Hygiene 16, 325 (1932).
Conditions:
Room Temp: 298 $\pu{K}$
Compiler:
Methodology:
The solubility was determined by mixing definite quantities of pentachloroethane with a large volume of water and measuring the volume of the undissolved pentachloroethane.
Sample Information:
- Commercial grade, further purified by washing with $\ce{NaHCO3}$ solution and then redistilled.
- Distilled.
Measurement Errors:
Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.
System Components:
- Pentachloroethane, $\ce{ C2HCl5 }$; [76-01-7] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | S2:1 ($\pu{cm3/g}$) | 100w1 a | $x_{1}$ a |
|---|---|---|---|
| 25 | 2.9 x 103 | 0.0346 | 3.08 x 10-5 |