SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 467
Source Publication
Conditions:
Room Temp: 298 $\pu{K}$
Compiler:
Methodology:
A saturated aqueous solution was prepared by passing of water through a column which was packed with glass beads coated with trichloroethene. The saturated solution was then pumped through an extractor column and trichloroethene was extracted directly into an analytical column. The samples were analyzed with a liquid chromatograph equipped with both an UV absorbance and a fluorescence detector with excitation filters. The peak area was established using a Hewlett-Packard recorder.
Sample Information:
- Eastman Kodak Co., commercial quality, used as received.
- Double distilled.
Measurement Errors:
Ambient temperature: ±1 K (compiler).
Mass concentration (m/v) (1): Not specified.
System Components:
- Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $C_{1}$ (mol/m3) | 100w1 a | $x_{1}$ |
|---|---|---|---|
| 25 | 10.4 | 0.1369 | 1.879 x 10-4 |