SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 467
Source Publication
Munz, C. D.; Ph.D. Dissertation, Stanford University, Stanford, CA 1985, 306 pp.
Conditions:
Room Temp: 283 - 303 $\pu{K}$
Compiler:
Methodology:
The multiple equilibration technique with direct aqueous injection into a gas chromatograph was used to determine the dimensionless Henry's law constant. A known volume of liquid and gas was introduced into a syringe and allowed to equilibrate. The ratio of gas to liquid volume was maintained constant. While vapor samples were injected directly into a gas chromatograph, the liquid samples were preconcentrated by liquid-liquid extraction before analysis. The experiments were carriedout in duplicates.
Sample Information:
- J. T. Baker Chemicals Co., NJ, >99.5% pure.
- Distilled and deionized.
Measurement Errors:
Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±0.0077 std. dev.
System Components:
- Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $\rho, (20^{\circ}C)$ (g/L) | 100w1 a | $x_{1}$ | $k_{\rm{H}}$ (m3 atm mol-1) |
|---|---|---|---|---|
| 10 | 1.21 | 0.1210 | 1.661 x 10-4 | 0.192 |
| 20 | 1.18 | 0.1180 | 1.620 x 10-4 | 0.326 |
| 30 | 1.15 | 0.1150 | 1.578 x 10-4 | 0.535 |