SDS Volume

Volume 67. Halogenated Ethanes and Ethenes with Water, p 467

Source Publication

Munz, C. D.; Ph.D. Dissertation, Stanford University, Stanford, CA 1985, 306 pp.

Conditions:

Room Temp: 283 - 303 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

The multiple equilibration technique with direct aqueous injection into a gas chromatograph was used to determine the dimensionless Henry's law constant. A known volume of liquid and gas was introduced into a syringe and allowed to equilibrate. The ratio of gas to liquid volume was maintained constant. While vapor samples were injected directly into a gas chromatograph, the liquid samples were preconcentrated by liquid-liquid extraction before analysis. The experiments were carriedout in duplicates.

Sample Information:
  1. J. T. Baker Chemicals Co., NJ, >99.5% pure.
  2. Distilled and deionized.
Measurement Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±0.0077 std. dev.

System Components:
  1. Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $\rho, (20^{\circ}C)$ (g/L) 100w1 a $x_{1}$ $k_{\rm{H}}$ (m3 atm mol-1)
101.21 0.12101.661 x 10-40.192
201.18 0.11801.620 x 10-40.326
301.15 0.11501.578 x 10-40.535

Download Data   link to XML output link to JSON output link to JSON-LD output