SDS Volume
Volume 67. Halogenated Ethanes and Ethenes with Water, p 466
Source Publication
McNally, M. E.; Grob, R. L.; J. Chromatogr. A 1984, 284, 105-16.
Conditions:
Room Temp: 303 $\pu{K}$
Compiler:
Methodology:
Standard trichloroethene solutions of increasing concentration were prepared in volumetric flasks as described elsewhere [1].The aqueous organic liquid phase was 25 mL and the vapor phase above the mixture was 35 mL The system was allowed to reach equilibrium in a constant temperature bath and then a sample was injected into the gas chromatograph. Values reported are an average of at least 5 measurements.
Sample Information:
- Chemical Service, West Chester, PA., USA., purest grade available.
- Distilled and run through two Barnstead purification cartridges.
Measurement Errors:
Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±3.2% std. dev.
Methodology Citation
1 McNally, M. E.; Grob, R. L.; J. Chromatogr. A 1983, 260, 23-32.
System Components:
- Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | Cm1 (g/dm3) | 100w1 a | $x_{1}$ a |
|---|---|---|---|
| 30 | 743.1 | 0.07458 | 1.023 x 10-4 |